Effect of the X-Ray on the Etch Rate Velocities (VB and VD) of the Nuclear Track Detector CR-39

Document Type : Research Paper

Authors

1 Physics Department, College of Science, Kirkuk University, Kirkuk, Iraq.

2 Department of physics, College of Science, Kirkuk University, Kirkuk, Iraq.

3 Physics Department, College of education-Hawija, Kirkuk University, Kirkuk, Iraq.

Abstract

The paper aims to study the effect X-Ray on different parameters of the nuclear track detector CR-39 irradiated with alpha particle. The parameters are tracks diameter, the Bulk etch rate, Track diameter growth rate. The detectors were exposed to X-Ray of voltage 5 kV and current 0.01 mA for different periods of time (0.5-2.5) h with step 0.5 h before and after irradiation with alpha particles of energy 2.5MeV emitted from 241Am source. It was found that the detector response in the case of irradiation with (X-ray+Alpha) is greater than that in the case (Alpha+X-ray) as compared to the slandered one irradiated with alpha particles only. It was also found that the track diameters and the bulk etch rate increase with the progress of the exposure time to X-ray for both cases, before and after irradiation with alpha particles.

Keywords


[1]          D. A. Young, "Etching of Radiation Damage in Lithium Fluoride", Nature, 128, 375 (1958).
                                                                                                                                     
[2]          S. H. S. Al – Nia'emi, "Effect of electromagnetic radiation on the properties    of nuclear track detector CR-39 and building of the electrochemical etching system" Ph.D. Thesis, College of Science, University of Mosul (1998).  
 
                                                                                    
[3]          L. A. S. Pereira, C. A. T. Sáenz, C. J. L. Constantino, E. A. C. Curvo, A. N. C. Dias, C. J. Soares, & S. Guedes, "Micro-Raman spectroscopic characterization of a CR-39 detector” Applied spectroscopy, 67(4), 404 (2013).
                               
[4]          Nada M. Hassan, Ahmed A. Ibrahim, "Effect of Heat Treatment on Bulk Etch Rate Activation Energy of CR-39 Detector ", Kirkuk University Journal, 11(4), 1 (2016) (in Arabic).
 
[5]          M. Sadowski, E. M. Al-Mashhadani, A. T. Szydlowski, T. Czyzewki, L. Glowacka  M. Jaskola, C.  Rolfs, and M. Wielunski, " Comparison of responses  of   CR-39 and PM-355 Track detectors to fast protons, deuterons and 4He ions    with energy range 0.2-4.5 MeV ", Radiation Measurements, 25(1-4), 175 (1999).      
 
                                                                         
[6]           S. Manzoor, S. Balestra, M. Cozzi, M. Errico, G. Giacomelli, M. Giorgini,  & V. Popa, "Nuclear track detectors for environmental studies and  radiation monitoring", Nuclear Physics B-Proceedings Supplements, 172, 92 (2007).
                                                              
[7]          Wathab Hazim Yousif , " Study The Recording Characteristics and Etchant on CR-39 Nuclear Track Detector by Using Some Chemical Solutions " M.Sc. thesis, Department of physics, College of Science, Kirkuk University, Iraq (2018) (in Arabic).
 
[8]          S. Singh, A. Neerja, “The effect of gamma-irradiation on the activation energy of bulk and track etching in CR-39 plastic track detector”, Radiation measurement, 42, 1507 (2007).       
                      
[9]           Suzan Bahadden Mohammad, " Finding of Optimum Etching Condition for Nuclear Track Detector CR-39 and the Effect of Laser " M.Sc. Thesis, Department of physics, College of Science, Kirkuk University, Iraq (2014). ).(in Arabic).
            
[10]       Ammar A. A. Al-Battawy, Khalid Ali, Amer H. Ali, " Effect The Variation of X-Rays Voltage Tube on the Etching Parameters of CR-39 Nuclear Track Detector ", 3rd International Advances in College of  Science, University  Baghdad, 2251,  (2009). (in Arabic) .
  
[11]      J. Rojas-Herrera, H. G. Rinderknecht, A. B. Zylstra, M. Gatu Johnson, D. Orozco, M. J. Rosenberg, H. Sio, F. H. Seguin, J. A. Frenje, C. K. Li, and R. D. petrasso   "Impact of x-ray dose on the response of CR-39 to 1–5.5 MeV alphas ", Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA, 86, 033501 (2015).
                                                                                                                                         
[12]       Ammar A. A. Al-Battawy," Effect of the X-Ray Exposure Time on the Nuclear Track Detector CR-39 ", Tikrit Journal of Pure Science, 14(1), 124 (2009). (in Arabic).
 
[13]       Yasir Y. Kasim , "Bulk Etch Rate of CR-39 Track Detector Exposed to Gamma Dose Using D-Le Method ",  Jordan Journal of Physics , 8(4),  217 (2015).(in Arabic).
 
[14]      Yasir Y. Kasim , " Formulation of an experimental equation for variation of the  general etch rate of the CR-39 nuclear detector with etching time and radiation dose ",  Journal of Education and Science , 23(43), 120 (2010).(in Arabic).